UPS ATLANTIS A03-OP1502P-RC 1500VA/1350W RACK 2U DOPPIA CONVER.-INTERF.EPO- 3 BATT.12V/9A- SLOT X SK SNMP -GARANZIA 2 ANNI

A03-OP1502P-RC

Cod. Articolo V12118

615,03 €
Tasse incluse Spedito entro 2-4 giorni
Quantità
Ultimi articoli in magazzino

Descrizione

Power Rating (VA): 1500

Power Rating (W): 1350

Input (Low Line Transfer):

- 80VAC-300VAC (load <=30%±5%)

- 120VAC-300VAC (load <=60%±5%)

- 140VAC-300VAC (load <=80%±5%)

- 160VAC-300VAC (load <=100%±5%)

Frequency Range: 40Hz to 70Hz

Power Factor: >0,99 (Normal Voltage)

Output

- Voltage: 208/220/230/240VAC

- AC Voltage Regulation: ±1%

- Frequency Range: 50Hz (±0.5%) or 60Hz (±0.5%)

- Waveform: Pure SineWave

- Crest Ratio: 3:1 (Max)

- Harmonic Distortion: <3% THD (liner Load) | <5% THD (Non liner Load)

Transfer:

- AC->Battery: Zero

- INV->ByPass: Less than 4ms (typical)

WaveForm (Batt. Mode): Pure Sinewave

Efficiency:

- AC Mode = 89%

- Battery = 85%

- ECO = 97%

Battery

- Voltage: 36VDC

- Capacity: 12V/9.0Ah

- Quantity: 3

- Recharge Time: 4 hours to (90%)

- Type: Sealed Maintenance Free Lead Acid VRLA Type

- Design: Easy-swappable battery design

- Charging Voltage: 41,1VDC ±1%

- Charging I: 1.0A Max

Indicators LCD Display

- UPS status | Load level | Battery level | Input/Output/battery info | Discharge time and Fault indicators

Backup Times:

- 1350w up to 2:30m

- 1013w up to 5:30m

- 675w up to 9:30m

- 338w up to 22m

Protection:

- 105% < Overload AC <110% Overload Warning UPS transfers to ByPass after 10 minutes

- 110% < Overload AC <130% Overload Warning UPS transfers to ByPass after 1 minutes

- Overload AC >130% Overload Warning UPS transfers to ByPass after 3 seconds

- 105% < Overload Battery <110% Overload Warning UPS shut down after 10 minutes

- 110% < Overload Battery <130% Overload Warning UPS shut down after 1 minute

- Overload AC >130% Overload Warning shut down after 3 seconds

- 110% < ByPass <120% Overload Warning UPS shut down after 30 minutes

- 120% < ByPass <130% Overload Warning UPS shut down after 10 minutes

- ByPass >130% Overload Warning UPS shut down after  1 minute

- Overload Inverter (>100%)

- Short Circuit INV: Electric Circuit

- Short Circuit AC: ICB & Electric Circuit

- Battery Over-drain Two stages: Controlled Battery Low Warning & Cut Off

- High Surge Level Immunity (>7KV)

Advanced:

- Fan detect protection and Fan speed control

- Programmable Outlets (4) (Turn ON/Off Delay and Turn Off Threshold)

- ECO mode

Connections

- Output 8xIEC 320 C13 (Battery Power Supplied)

- RS232 and USB (HID)

- Intelligent Slot for SNMP Card

- EPO / ROO

- Battery Bank Connection

Dimensions (WxHxD): 438 x 88 x 430 mm

Net Weight 14,0 Kg (with Battery)

Temperature: 0°-40° C

Humidity: 20-90% (non-condensing)

Dettagli del prodotto
A03-OP1502P-RC
1 Articolo

16 altri prodotti della stessa categoria: